3V Blade Combination Fire & Smoke Dampers
The FSD-3V series are UL, ULC and California State Fire Marshal listed as both a UL555 fire and UL555S smoke damper. Available in both 1-1/2 and 3 hour fire ratings, the FSD-3V series is available with UL555S Class I or Class II leakage ratings and a variety of electric and pneumatic actuators
  • Available in 1-1/2 or 3 Hour fire ratings, with either UL Class I or Class II leakage.
  • Available for both vertical and horizontal mount.
  • Full range of factory sleeve gauges and lengths available
  • Available with 24VAC, 120VAC or 230VAC electric actuators or Pneumatic actuators
  • Provided with a resettable heat responsive thermostat (O/R). Thermostat with built in switch (STO/R) or dual thermostat with override capability (DTO/R) available as add on options.
Submittal

Submittal - Triple-V Combination Fire/Smoke Damper - Class I Leakage - 1-1/2 or 3 Hour - FSD-3V-S-211
Submittal - Triple-V Combination Fire/Smoke Damper - Class II Leakage - 1-1/2 or 3 Hour - FSD-3V-S-212
Submittal - Out of Wall Triple-V Combination Fire/Smoke Damper - Class I Leakage - 1-1/2 Hour - FSD-3V-OW-211
Submittal - Out of Wall Triple-V Combination Fire/Smoke Damper - Class II Leakage - 1-1/2 Hour - FSD-3V-OW-212
Submittal - Front Access O/W Triple-V Combination Fire/Smoke Damper - Class I Leakage - 1-1/2 Hour - FSD-3V-FA-211
Submittal - Front Access O/W Triple-V Combination Fire/Smoke Damper - Class II Leakage - 1-1/2 Hour - FSD-3V-FA-212
Submittal - Triple-V Corridor Fire/Smoke Damper - Class I Leakage - 1 Hour - FSD-3V-CR-211
Submittal - Triple-V Corridor Fire/Smoke Damper - Class II Leakage - 1 Hour - FSD-3V-CR-212

Accessories

Submittal - Single Thermostat Operator Release with M/S - STO-R
Submittal - Microswitch for Multiblade Dampers - M/S
Submittal - Remote Control Box - RCB-1-2-3
Submittal - Fusible Link Based Operators - PFV-EFL
Submittal - Single Thermostat Operator Release - O/R
Submittal - Framed Retaining Angles for UL Fire Damper Installations - FRA
Submittal - Smoke Detector
Submittal - Double Thermostat Override Release with M/S - DTO/R

Installation Manuals

Installation Instructions - Fire Smoke Dampers
Installation Instructions - Out of Wall / Partition for Fire Dampers and Combination Fire Smoke Dampers
Installation Instructions - UL Installation Instructions for FSD-3V-CR Corridor Dampers
Installation Instructions - Factory Installed Smoke Detector Mounting Detail
Installation Supplement - Installation in Concrete Floor with Steel Deck

Miscellaneous

Damper Enclosures and Transitions

Copyright © 2016 - Metal Industries, Inc. - All Rights Reserved